To use this function, it is necessary at least to have installed firmware version 4.29 on the REG-DIN-8 and to use a RegConfig version 4.29 or later.
...
Enter Configuration/2 and set the activation offset for the Integration function
...
Go to the Zones page and create the desired zones (in the example, 3 zones have been created) by associating a room probe or sensor. Then, in the Integration column, choose the sum referring to one of the 4 available dehumidifiers (∑D1, ∑D2, ∑D3, ∑D4), in the example the first has been chosen:
...
If the zones are served by the same duct unit, associate each zone with the same dehumidifier. In the example below, the first is associated with all zones:
...
4. Sempre rimanendo nella pagina Zone entrare in Configurazione Zona/2 e inserire un valore da 0 a 100 sulla casella indicata in base al peso delle singole stanze:
...
Still remaining in the Zones page, enter Configuration Zone/2 and enter a value from 0 to 100
...
in the box indicated according to the weight of the individual room:
5. Spostarsi nella pagina Deumidificatori (D1) impostare il comando Integrazione su “Attivo se richiesto” in estate e/o in inverno in base alle necessità dell’impianto. Per quanto riguarda le impostazioni delle portate d’aria la velocità media viene ignorata:
la velocità bassa diventa la minima
la velocita alta diventa la massima
La velocità attuale dell’uscita 0/10V è la somma delle portate delle singole zone che fanno riferimento al deumidificatore 1, nell’esempio riportato 15+15+30 = 60, quindi 6 V.
Se la somma fosse inferiore a 30 o superiore a 90, l’uscita 0/10V sarebbe limitata a 3 V o 9 V.
...
Move to the Dehumidifiers (D1) page and set the Integration control to “Active if
...
requested” in summer and/or winter according to the needs of the system. Concerning Air Flows settings, the medium speed is ignored:
...
Low speed becomes the minimum
...
High speed becomes the maximum
The current speed of the 0/10V output is the sum of the flow of the individual zones that refer to the dehumidifier 1, in the example above 1530+15+30 45 = 6075, therefore 6V7,5V.
If the sum were less than 30 0r 10 or greater than 90100, the 0/10V would be limited to 3 1 V or 9 10 V.
...